Sensor solutions

Vertical doors

Sensoren für Vertikaltore

Sensors for vertical doors

 

Various sensor components are available for the safe opening and closing of your vertical doors. BBC Bircher Smart Access offers you a comprehensive range of door sensor systems.

The tried and tested loop detectors can be used to activate the vertical doors. However, a radar motion detector such as the Herkules 2E is also ideal.
Electric safety edges can be used at the main closing edge. These offer the best protection for people and vehicles against being crushed or trapped in the door.

For reliable signal transmission, we recommend the ExpertSystem XRF wireless radio signal transmission system.

Download industrial doors brochure

Helios 2T
ProLoop

Activation

Radar field for activation

Security

AIR curtain for presence detection

ExpertSystem XL
LBGate
ExpertSystem XRF

Helios 2T

Radar motion and AIR presence sensor for industrial doors

ProLoop 2

ProLoop

Loop detectors for industrial gates, barriers, parking lot systems and bollards

ExpertSystem XL

ExpertSystem XL

Modular safety edge system for door applications

LBGate

Light barriers for detecting people, objects and vehicles

ExpertSystem XRF

ExpertSystem XRF

Wireless signal transmission system for door applications

Zum Produkt

Technical data

Device dimensions (W × H × D)

  • XRF-T.2 (transmitter): 50 × 121 × 23 mm
  • XRF-TI (transmitter): 18 × 194 × 18 mm
  • XRF-R.1 (receiver): 50 × 121 × 23 mm
  • XRF-R.2 (receiver): 75 × 121 × 24 mm
  • XRF-RD (receiver): 22.5 × 94 × 91 mm
  • XRF-TW (transmitter): 66 × 58 × 16 mm
  • XRF-TW (magnet): 66 × 17 × 16 mm

Electrical data

Frequency

868 MHz

Transmitter XRF-T.2, XRF-TW

  • Operating voltage: Lithium battery 3 V (CR2450N)
  • Battery life: Type. 1.2 years

Transmitter XRF-TI

  • Operating voltage: Inorganic lithium battery 3.6 V
  • Battery life: Typ. 7 years

Receiver XRF-R.1, XRF-R.2, XRF-RD

  • Operating voltage: 12-36 V AC / 48-62 Hz
    12-36 V DC
  • Power consumption: Max. 1 W
  • Outputs (redundant): Relay 24 V AC/DC, 1 A
  • Option: 8.2 kOhm parallel resistor

General data

  • Range: 100 m under optimal conditions
  • Protection class: IP65 (except XRF-RD = IP20)
  • Approvals:
    EN ISO 13849-1 (PL d, Cat. 3)
    EN 300 220
    EN 301 489

Note:
The ExpertSystem XRF signal transmission systems are type-tested in combination with Bircher safety edges.
Technical specifications and recommendations for our products are based on experience and are intended as a guide for the user. Information in brochures and data sheets does not guarantee specific product properties. Special product properties, which we confirm in writing or individually in individual cases, are excluded from this. We reserve the right to make changes due to technical developments.

Further sensor solutions